Reference "Save the Domes" by Alfred Twu
https://www.ocf.berkeley.edu/~atwu/firstcultural/domes/domes-story.pdf
Reference: http://usgbcma.org/net-zero-energy-buildings
All the sketches of the domes are by Alfred Twu.
All the sketches of the domes are by Alfred Twu.
Dome 14
Minor envelope improvement
GTAC installed for .for space heating
HPWH for water heating
Dome 13
Minor envelope improvement
GTAC installed for .for space heating
HPWH for water heating
Dome 8
Complete envelope improvement
HPWH for water heating
Dome 7 - office
Complete envelope improvement
Interested in getting involved?
Fill in a proposal here.
Path to ZNE
1. Constraints (physical/bureaucratic/monetary)
Physical and monetary constraints determine whether or how close a project gets to achieving full ZNE. Physical conditions such as the amount of sun and average year round temperatures at a site will affect electric generation from solar panels, for example, and the actual size and landscape will affect what can actually be installed. Bureaucratic constraints such as zoning and permits could also be a factor. Budgetary constraints are perhaps the greatest determining factor in how much time, human power, and resources can be invested into a project.
2. Accuracy (baseline estimate, assumptions, and models)
The assumptions and accuracy of the baseline, future consumer behavior, the efficiency of the energy strategies, and the energy modeling all factor in to if or how close a project gets to ZNE.
Baseline
Envelope
Energy Efficiency
On-site Production
Follow-up
Once the baseline has been established, efficiency strategies, which are defined as any interventions that reduce energy consumption without reducing the overall level of services, can then be evaluated through modeling. Site performance post retrofits and interventions is assessed by comparison against the baseline.
In every step of the process the system is re-evaluated to assess the efficacy of the retrofits and installations.
Cutaway View
Aerial View
Cross-section
Wall-section
1 - 4
<
>
Summary
Energy Usage
Building
Historical Usage
Load Bearing Elements
Infrared Imaging
What retrofits were made ? (Description).
Dome 7 was remodeled into an ADA (Americans with Disabilities Act) compliant office, which includes a half bath and no space heating capabilities. Dome 8 has remained a residential dome. The 2” polyurethane foam from both domes was delaminated and replaced with a 4” soy based spray foam. Insulation was also added to the concrete slab. The windows, doors, and skylight were replaced with air tight, energy efficient models. All electrical and plumbing was replaced. The baseline previously determined that 63% of energy use in the Domes can be attributed to water heating. For this reason the electric water heater in Dome 8 was replaced with a heat pump model with twice the efficiency.
What was the setup of this study in Dome 8? (Design)
Dome 8 is continuously monitored head to head against control Domes 6 and 10. Dome 6 and 10 have not undergone modifications of any kind except for regular maintenance. Domes 6 and 10 also have the original Honeywell HW4000 space heater.
What was the motivation behind this study? (Motivation).
The purpose of this study was twofold:
· First, given the challenges of the original baseline study, to retrofit 3 domes with multisensory data loggers to collect real-time data in order to validate past work and to build a more accurate model of the baseline; and
Second, to update domes 7 & 8, specifically to improve the dome envelope and to compare conventional electric hot water heating with more advanced heat pump technology.
How was performance measured? (Methods)
Performance is measured in real time, using data loggers connected to three different sets of sensors:
1) Current transformer devices that were installed directly into the each Domes’ breaker box and measures current, voltage, and power output;
2) Relative humidity and temperature sensor to monitor internal climate and compared to local meteorological data;
3) Water temperature and flow rate to monitor performance of domestic hot water heating.
Comparing Space Conditioning Technologies in Domes 13/14/15
The second domes study targeted energy efficiency modifications (ZNE step 3) and was made possible by PG&E. This study began during Spring Quarter 2013 in domes 13, 14, and 15, and was designed to compare the use of various heat pump technologies in the domes. Specifically, this study targeted the top two sources of energy use in the domes, space and hot water heating. Minor envelope upgrades were also made to Domes 13, 14, and 15, although these upgrades were not nearly as expansive as Domes 7 and 8 in Energy Experiment 1.
What retrofits were made ? (Description).
Domes 13, 14, and 15 were upgraded with slab insulation, new energy efficient doors and skylights as well as with less energy intensive LED lighting. Unlike Dome 8, these domes, did not have energy efficient windows installed and did not receive upgraded wall insulation. Domes 13/14/15 were each originally built with a 30 gallon electric hot water heater. As part of this study, these three units were replaced with one 80 gallon model connected in parallel to all three domes.
What was the motivation behind this study? (Motivation).
To study and compare the effects of various heat pump technologies in Domes 13, 14, and 15. Heat pump technology replaced the conventional electric resistor type hot water and space heaters. Furthermore, as the domes were not originally built with cooling, the goal of this study was to test two types of dual heating/air conditioning heat pump systems (GHP/GTAC vs. AHP/PTAC) that would both save energy and give the residents the added option of domestic cooling. This expanded level of service also carries with it the potential for increased use and therefore increased energy usage, which we were interested in testing.
What was the setup of this study? (Design)
GTAC systems were installed in Domes 13 and 14. Meanwhile, a PTAC system was installed at Dome 15 for comparison. These were both compared to the Honeywell HW4000F units in domes 6, 8, and 10.
The efficiency of the 80 gallon heat pump water heater was compared to the 50 gallon heat pump water heater in dome 8 as well as to the conventional, electric hot water heater in domes 6 and 10.
For the purpose of both comparisons it is important to note that Domes 13, 14, and 15 have an upgraded envelope compared to control Domes 6 and 8, although the upgrades are not as comprehensive as Dome 8.
Domes 13/14/15 were each originally built with a 30 gallon electric hot water heater. As part of this study, these three units were replaced with one 80 gallon model connected in parallel to all three domes.
How was performance measured? (Methods)
Performance is measured in real time, using a data logger that is connected to 3 different sets of sensors:
1) Current transformer devices that are installed directly into the each Domes breaker box and measures current, voltage, and power output;
2) Relative humidity and temperature sensor to monitor internal climate and compared to local meteorological data;
Water temperature and flow rate to monitor performance of domestic hot water heating as well as flow rate on the ground water loop for the GHP systems.
Heat Pump
HPWH
PTAC
GTAC
Heat pumps use external power to move thermal energy against the natural temperature gradient from a region of lower temperature (heat sink) to a region of higher temperature by employing a refrigerant cycle. Refrigerant cycles work by passing a refrigerant such as Freon through a compressor, followed by a condenser coil, an expansion valve, and finally an evaporator coil before looping back. For a detailed description, refer to the image below.
This same technology is used in many modern AC and refrigeration units. Heat pumps are ideally suited to regions of relatively mild weather conditions and often include a backup electric resistor in order to employ traditional heating when necessary. Compared to the original electrical heater, a heat pump can save up to 85% energy consumption while providing air conditioning service in both summer and winter.
http://www.vent-axia.com/heatpump/how
https://www.energystar.gov/products/water_heaters/high_efficiency_electric_storage_water_heaters/how_it_works
Heat pump water heaters use electricity to pump heat from one place to another rather than to directly generate heat. Refrigerators work by collecting heat from inside a chamber and dumping it to the environment. HPWH work in reverse, collecting heat from the surroundings and pulling it in to a chamber to heat water.
Package-terminal Air Conditioning (or Air-source Heat Pumps) utilize the outdoor air to release and absorb heat for indoor space heating/cooling effect. These systems use an exterior fan and a refrigerant cycle to transfer heat between the dome inside and the outdoor air.
Ground source-terminal Air conditioning (or Ground-source Heat Pumps) work in the same manner as PTACs except that instead of exchanging heat with the ambient air, GTACs exchange heat with the ground. This is accomplished through an intricate, underground circuit of pipes to transfer heat between the dome and the ground. These systems can be very efficient but also very costly and difficult to install.
Energy savings since March 2013: